What Can a 2,000-Watt Generator Run?

A 2,000-watt inverter generator usually delivers about 1,600 running watts, with 2,000 watts available for a second or two while a motor starts. To keep it from running flat out, plan on a steady load of about 1,333 watts. Generators this size usually have no 240-volt outlet, so well pumps and central AC are out.

Starting watts2,000
Running watts1,600
Comfortable steady load1,333

Common combinations

Each row assumes everything in it runs at once, with the biggest motor starting while the rest are on.

LoadRunning WStarting peak WFits?
Fridge, freezer, lights and Wi-Fi7901,990Yes
Same, plus a 1/2 HP sump pump1,8403,040No
Gas furnace, fridge, lights and TV1,4402,640No
Well-water home essentials (1/2 HP well pump)1,7902,990No
Essentials plus a window AC1,6403,440No
Essentials plus 3-ton central AC5,08011,380No
Whole house with gas heat and gas appliances10,90519,105No
Whole house, all-electric21,73029,930No

Runs on its own

  • Sump pump (1/3 HP)
  • Refrigerator
  • Freezer (chest or upright)
  • Microwave
  • Coffee maker
  • Gas furnace blower (1/3 HP)
  • Boiler, gas or oil (burner + circulator)
  • Dehumidifier
  • LED lighting (whole house)
  • Wi-Fi router + modem
  • TV
  • Computer + monitor
  • Phone & laptop chargers
  • Gas dryer
  • CPAP machine
  • Oxygen concentrator

Too big on its own

  • Sump pump (1/2 HP) (2,150 W to start)
  • Well pump (1/2 HP) (needs a 240-volt outlet)
  • Well pump (3/4 HP) (needs a 240-volt outlet)
  • Well pump (1 HP) (needs a 240-volt outlet)
  • Electric cooktop (2 burners) (needs a 240-volt outlet)
  • Dishwasher (1,500 W running)
  • Gas furnace blower (1/2 HP) (2,350 W to start)
  • Central AC or heat pump (2 ton) (needs a 240-volt outlet)
  • Central AC or heat pump (3 ton) (needs a 240-volt outlet)
  • Central AC or heat pump (4 ton) (needs a 240-volt outlet)
  • Central AC or heat pump (5 ton) (needs a 240-volt outlet)
  • Window AC (10,000 BTU) (2,700 W to start)
  • Space heater (1,500 W running)
  • Garage door opener (1/2 HP) (2,350 W to start)
  • Washing machine (2,250 W to start)
  • Electric dryer (needs a 240-volt outlet)
  • Electric water heater (needs a 240-volt outlet)
  • EV charger (Level 2) (needs a 240-volt outlet)

Cost and fuel

A 2,000-watt inverter generator typically costs $450–$1,000. To power circuits in your home rather than running extension cords, add an inlet box and a transfer switch or breaker interlock installed by an electrician, usually $600–$1,800.

At a steady 1,333-watt load it burns roughly 0.17 gallons of gasoline an hour, or about 4 gallons a day if it runs around the clock. Lighter loads use less. Store fuel safely and plan how you'll refill during a long outage.

Have a different list? Run the calculator with your own appliances. Nearby sizes: 3,000 W.