What Size Generator Do I Need to Run a Furnace or Boiler?
A gas or oil furnace still needs electricity: the blower fan, igniter and controls stop without power. The blower is a modest motor, so keeping the heat on in a winter outage takes far less generator than most people expect.
| Appliance | Running / starting W | On its own | With fridge, lights and Wi-Fi |
|---|---|---|---|
| Gas furnace blower (1/3 HP) | 700 / 1,400 | 2,000-watt 10 kW standby | 3,000-watt 10 kW standby |
| Gas furnace blower (1/2 HP) | 875 / 2,350 | 3,000-watt 10 kW standby | 3,000-watt 10 kW standby |
| Boiler, gas or oil (burner + circulator) | 300 / 700 | 2,000-watt 10 kW standby | 3,000-watt 10 kW standby |
Smallest portable (by starting watts) and smallest standby generator on natural gas, keeping about 20% headroom.
Tips
- Furnaces are sensitive to unstable power; an inverter generator or a standby unit gives cleaner electricity.
- Many furnaces are hard-wired: an electrician can add a transfer switch or a plug-in cord kit so a portable can run it safely.
- Electric furnaces and heat-strip backup are a different story: they need 10–20 kW, often more than the rest of the house.
See also what size generator you need for your house, the appliance wattage chart and what each generator size can run.